Step: Upgrade the 8.x model and install the new reports
1.
Navigate to the Unica\ProductNameReportsPack\CognosN directory, where N is the version of your Cognos installation..
2.
Copy the reports archive .zip file (for example Unica Reports for Campaign.zip) to the directory where your Cognos® deployment archives are saved.
The default location is the deployment directory under your IBM® Cognos® installation and it is specified in the Cognos® Configuration tool installed with the Cognos® Content Manager. For example: cognos\deployment
In a distributed IBM® Cognos® environment, this is a location on the system running the Content Manager.
3.
If the Reports Pack installation directory and Framework Manager are on different machines, locate the cognos10\model directory under the Reports Pack installation directory, and copy it to the directory on the machine where your Framework Manager is installed.
4.
Only if you did not install your IBM® EMM product to the default directory (C:\Unica on Windows), you must update some upgrade scripts as described in this step.
You must update the scripts listed here. The scripts you must update differ, depending on the reports package, as shown below.
Also, you should take into consideration the 8.x version from which you are upgrading. You do not have to update the scripts that refer to earlier versions. For example, if you are upgrading Campaign reports from version 8.5.0, you would not have to update the upgrade80to81.xml and upgrade81to85.xml scripts.
The scripts are all located in the ProductNameReportsPack\cognosN\ProductNameModel directory under your IBM® EMM product installation.
The N in the path refers to the Cognos version number.
Campaign
*
*
*
*
eMessage
*
*
*
Interagir
*
*
*
*
Líderes
*
*
Campaign with Operações de Marketing
*
*
*
Operações de Marketing
*
*
*
*
upgrade86to90_DB2.xml (for DB2 database only)
*
upgrade86to90_Oracle.xml (for Oracle database only)
*
upgrade86to90_Sqlserver.xml (for SQLServer database only)
Marketing Distribuído
*
*
Interaction History
*
Modelador de Atribuição
*
In each script, edit file paths that point to directories where localized language versions of the models are stored to reflect your product install location. Make this change for every language your users need. For example:
install_directory \ReportsPackCampaign\cognosN\CampaignModel\translations\L\translations.txt
The N in the path refers to the Cognos version number.
The L in the path refers to one of the following language indicators.
*
*
*
*
*
*
*
*
*
5.
Open Cognos® Connection.
6.
Select Administer Cognos Content > Configuration > Content Administration.
7.
Click the New Import button on the toolbar and import the reports folder.
8.
Open Cognos® Framework Manager and open the project for the version from which you are upgrading.
9.
Select Project > Run Script.
10.
You must run the scripts listed here. The scripts you must run differ, depending on the reports package, as shown below.
Also, you should take into consideration the 8.x version from which you are upgrading, as follows.
*
You do not have to run the scripts that refer to earlier versions. For example, if you are upgrading Campaign reports from version 8.5.0, you would not have to run the upgrade80to81.xml and upgrade81to85.xml scripts.
*
You must run the preUpgrade_86_fromanyversion.xml script for upgrades from all versions except 8.6.
The scripts are all located in the ProductNameReportsPack\cognosN\ProductNameModel directory under your IBM® EMM product installation.
The N in the path refers to the Cognos version number.
Campaign
*
*
*
*
*
eMessage
*
*
*
Interagir
*
*
*
*
*
Líderes
*
*
Campaign with Operações de Marketing
*
*
*
*
Operações de Marketing
*
*
*
*
*
upgrade86to90_DB2.xml (for DB2 database only)
*
upgrade86to90_Oracle.xml (for Oracle database only)
*
upgrade86to90_Sqlserver.xml (for SQLServer database only)
Marketing Distribuído
*
*
Interaction History
*
Modelador de Atribuição
*
11.
Publish the package to the Cognos® content store.
12.
Do the following in Cognos® Report Studio for each cross-object Performance by Cell and object-specific Performance by Cell report.
a.
Go to File > Report Package.
b.
Select Unica Campaign Package and click OK.
c.
d.
After the report is validated, click Close in the Validation Response window.
This is not required for Modelador de Atribuição or eMessage.
13.